Brushes are made of a filament blocked between two twisted metal wires.
The result is a brush with one helical (SIMPLE HELICAL brush).
If the brush is mounted on mechanical equipment, the metal rod is usually sheared on both sides. If the use is manual, on one side a part of the rod is free of filament to be used as a handle, usually ending with a circular ring or a plastic handle is welded.
The end of the brush can be folded down, making a small fan of filaments called “fan tip” which is used to prevent the cut wire from damaging the parts to be processed. For this purpose you can also make a “closed tip” with end ring or with the material that fills it up to the end. When a particular sturdiness is required, the brush can be built with four sealing wires, which can mount an M12 threaded connection.
The main feature of the brushes is the small core diameter, which makes them irreplaceable for the internal cleaning of pipes, gutters and interstices that are difficult to access. In addition, their flexibility can be used for cleaning curved surfaces.
The materials and sizes of the brush can be adapted according to the expected use of the brush.
The materials and sizes of the brush can be adapted according to the expected use of the brush. The right combination can create the ideal brush for you: discover the potential of each material below.
Maximum operating temperature: 120°C per uso permanente, -170°C per uso breve
Minimum operating temperature: -40°C
Tensile strength: 70-90 N/mmq
Electrical resistance: 1015 Ohm*cm
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: yes
Indications for use: Flexible material, high resistance to high and low temperatures and to chemicals.
Maximum operating temperature: 100°C
Minimum operating temperature: 0°C
Tensile strength: 32 N/mmq
Electrical resistance: 10^16 Ohm*cm
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: yes
Indications for use: High mechanical resistance, high resistance to chemical factors. It’s particulary suitable to chemical industry.
Maximum operating temperature: 60°C
Minimum operating temperature: 0°C
Tensile strength: 55 N/mmq
Electrical resistance: 10^13 Ohm*cm
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: yes
Indications for use: High mechanical resistance, high resistance to chemical factors. It has low level of humidity absorption and it is resistant to fire due to the component of chloride.
Maximum operating temperature: 30°C
Minimum operating temperature: -30°C
Tensile strength: 1900 N/mmq
Electrical resistance: 0,142 Ohm/mm2*m
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: no
Indications for use: High mechanical resistance, high resistance to chemical factors. It has low level of humidity absorption and it is resistant to fire due to the component of chloride.
Maximum operating temperature: 350°C
Minimum operating temperature: -30°C
Tensile strength: 2200 N/mmq
Electrical resistance: 0,142 Ohm/mm2*m
Chemical Resistance: low
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: no
Indications for use: Treatment of hard metals.
Maximum operating temperature: 350°C
Minimum operating temperature: -30°C
Tensile strength: 2200 N/mmq
Electrical resistance: 0,142 Ohm/mm2*m
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: Food industry, humid or aggressive environment.
Indications for use: Treatment of hard metals.
Maximum operating temperature: 170°C
Minimum operating temperature: -30°C
Tensile strength: 900 N/mmq
Electrical resistance: 0,063 Ohm/mm2*m
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: no
Indications for use: Non-aggressive treatment of metals.
Maximum operating temperature: 170°C
Minimum operating temperature: -30°C
Tensile strength: 950 N/mmq
Electrical resistance: 0,07 Ohm/mm2*m
Chemical Resistance: good
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: no
Indications for use: Non-aggressive treatment of metals, chemically aggressive environment.
Maximum operating temperature: 150°C
Minimum operating temperature: -150°C
Tensile strength: –
Electrical resistance: –
Chemical Resistance: low
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: no
Indications for use: High temperature and delicate surfaces.
Maximum operating temperature: 150°C
Minimum operating temperature: -150°C
Tensile strength: –
Electrical resistance: –
Chemical Resistance: low
FDA [Food and Drug Administration (U.S. Food and Drug Administration (U.S.) – room temperature only]: no
Indications for use: High temperature, similar to horse but with stronger bristles.
Unit weight: 1,4-1,5 g/cm3
Rate of take-back: Relatively low, around 8.5%; linen around 12%.
Toughness: dry 3-5 g/dtex, wet 120-130 g/dtex.
Elongation at break: dry 3-7%, wet 110-120%.
Elastic recovery: for an elongation of 2 % = 70 %. It is a relatively inelastic material.
Heat patterns:
Reaction to flames: It burns easily with a bright flame and releases a smell of burnt paper. Leaves an ash n.ot too voluminous and easily pulverized.
Electrical properties: antistatic fiber.
Hygroscopicity: Absorbs humidity well, the amount of water that it can absorb varies according to the processing that the fiber has undergone.
Emiliana Scovoli S.r.l.
Emiliana Scovoli s.r.l.
IT02632750358
Via Galvaligi, 1 42045 Villarotta di Luzzara (RE) Italy
Tel e Fax: (+39) 0522.820200
info@emilianascovoli.it